[情報] RivaTuner Version 2.09
說明頁:
http://www.guru3d.com/index.php?page=rivatuner
下載頁:
http://downloads.guru3d.com/download.php?det=163
Version 2.09:
Minor bugfixes:
The server no longer erroneously swaps RGB components and no longer causes
On-Screen Display to be rendered in unexpected color under Direct3D10 when
non-default OSD color is being used.
What's new:
Added ForceWare 175.xx drivers family support.
Updated databases for Detonator and ForceWare drivers. Added databases for
ForceWare 174.40, 174.51, 174.53, 174.60, 174.70, 174.74, 174.82, 174.85,
174.88, 174.93 and 175.12.
Added Catalyst 8.4 drivers detection. Please take a note that ATI continues
"old good" tradition of using the same build version of different driver
versions, so both Catalyst 8.3 and 8.4 will be detected as Catalyst 8.3 or
newer.
Updated Catalyst 8.4 certified SoftR9x00 patch script (for Windows 2000/XP
drivers only).
Updated PCI DeviceID database for AMD graphics processors. Added PCI
DeviceIDs for RADEON X1650 AGP and RADEON 3850 X2.
Update driver files database for 64-bit NVIDIA ForceWare drivers.
Unlocked previously available experimental AMD RV620 graphics processors
family support.
Added experimental NVIDIA G96 graphics processors family support.
Added experimental NVIDIA G100 (aka GT200) graphics processors family
support.
Added experimental driver-level multi-GPU fan control support for Quad-SLI
systems. Thanks to Jacob Freeman @ EVGA for testing driver-level fan control
with2x NVIDIA 9800GX2 system.
Now RivaTuner is able to detect driver version and display driver files info
for drivers using multiple driver files and active non-primary driver file.
Added experimental clock frequency stress-testing for NVAPI overclocking
interfaces. Please take a note that NVAPI's own stress testing is not ideal
yet and it is not available for some GPU families (e.g. G80) or may work
improperly for others. Due to this reason NVAPI clock frequency
stress-testing feature is disabled by default, however power users may enable
it using NVAPIClockTest registry entry.
Added set of technologies aimed to improve RivaTuner startup and usage safety
in conjunction with other hardware monitoring and diagnostics related tools:
Added low-level PCI controller access synchronization protocol. The protocol
serves for preventing possible PCI controller access collisions when multiple
tools are being started and scanning PCI buses simultaneously (e.g. detecting
supported hardware during OS startup). Please take a note that to take full
effect the protocol must be supported by other tools used simultaneously with
RivaTuner, so please ensure that you're using this version of RivaTuner with
the latest versions of other monitoring or diagnostics related software
products (e.g. Everest).
Previously used low-level I2C synchronization protocol is now also applied to
driver-level thermal monitoring function calls to prevent possible conflicts
between low-level I2C transactions and internal driver-level I2C
transactions.Please take a note that to take full effect the protocol must be
supported by other tools used simultaneously with RivaTuner, so please ensure
that you're using this version of RivaTuner with the latest versions of other
monitoring or diagnostics related software products (e.g. Everest).
Added hardware scanning synchronization protocol, aimed to optimize startup
process and reduce startup time when multiple tools are intensively scanning
hardware.
Now startup daemon routine displays warning message in case of driver load
failure (e.g. when the driver is blocked by antivirus tool).
Startup daemon self-deinstallation technology is disabled by default now. The
daemon no longer uninstalls itself from Windows startup when it fails to
apply any startup settings (e.g. due to driver load blocked by antivirus
tool). If needed, the technology can be re-enabled by setting
DontUninstallStartupDaemon registry entry to 0.
Updated bundled RivaTunerStatisticsServer v2.6.0 utility:
Now OSD rendering routines are compatible with WPF based applications.
Now the server's manifest file specifies full administrative privileges
requirement. If you're using Windows Vista with UAC enabled, it is
recommended to create scheduled task launching the server simultaneously with
RivaTuner to minimize amount of displayed UAC evaluation dialogs.
Changed sever's own OSD rendering behavior, now the server doesn't display 3D
API usage information in the OSD when framerate display is not requested by
a client application.
Updated pseudo-3D applications list.
Updated bundled D3DOverrider v1.6.0 utility:
Now the D3DOverrider's manifest file specifies full administrative privileges
requirement. If you're using Windows Vista with UAC enabled, it is
recommended to create scheduled task launching the utility simultaneously
with RivaTuner to minimize amount of displayed UAC evaluation dialogs.
Improved launcher module:
Added 'Show item in tray menu' option to regular launch item editor. By
disabling this option you may prevent some regular launch items from being
displayed in RivaTuner's tray menu. This option is helpful if you're
intensively use scheduled tasks and define many helper launch items, required
only for scheduled tasks.
Now you may select 'All files' as file type when browsing for application
associated with a launch item and this way start and non-executable file type
(e.g. WAV or MIDI) registered in the OS. Please take a note that 'Restore
settings after terminating application' option will not affect non-executable
file types.
Now RivaTuner stores application specific event markers in the event history
panel of hardware monitoring window, allowing you to analyze all item launch
events and reasons (e.g. item launch due to pressed hotkey, due to scheduled
task etc). This feature simplifies debugging complex dynamic hardware control
algorithms programmed via scheduler module etc.
Improved scheduler module:
Now you may specify custom scheduled tasks names in the task editor window to
improve scheduled tasks list readability.
Added 'Wait for application termination' option for 'Launch application'
tasks, allowing you to program sequentional tasks execution if needed.
Now you may select 'All files' as file type when browsing for application
associated with 'Launch application' task and this way start and
non-executable file type (e.g. WAV or MIDI) registered in the OS. Please take
a note that 'Wait for application termination' option will not affect
non-executable file types.
Now RivaTuner stores application specific event markers in the event history
panel of hardware monitoring window, allowing you to analyze all shceduled
tasks events and reasons (e.g. scheduled task launch due to core temperature
change from 50°C to 51°C). This feature simplifies debugging complex
dynamic hardware control algorithms programmed via scheduler module etc.
Improved hardware monitoring module:
Now you may use 'Override group name' option in each data source's properties
to define custom on-screen display group for it and override default OSD
grouping rule if needed,
Now RivaTuner is able to detect PLL shutdown and swicth to bus clock on G8x
and newer GPU families to provide dynamic memory clock frequency monitoring
on upcoming G96 graphics processors family.
Now RivaTuner uses BIOS PLL information tables on G9x and newer GPU families
to detect reference clock frequencies for core and memory PLLs if unknown GPU
is detected. If needed, reference clocks can be redefined via [CrystalClock]
section of RivaTuner.cfg file.
Improved SMART.dll hardware monitoring plugin. Now the plugin supports SMART
temperature reading for up to 8 hard drives instead of 4 hard drives in the
previous version.
Improved low-level diagnostic report module:
Now RivaTuner displays PLL table contents containing per-PLL reference clock
frequencies for G8x and newer display adapter families in 'NVIDIA VGA BIOS
information' diagnostic report category.
Unlocked undocumented SSAA and combined MSAA / SSAA antialiasing modes for
G8x and newer display adapters.
Now you may change external I2C fan controller detection retry counter using
ExternalFanControllerDetectRetry registry entry or completely disable
external I2C fan controller detection by setting this registry to 0.
Minor UI changes and improvements.
複製說明文字過來結果分項符號不見了0.0
造成版面行距很近不好閱讀,請到第一個連結說明頁觀看較清楚
謝謝
--
※ 發信站: 批踢踢實業坊(ptt.cc)
◆ From: 220.139.54.129
推
05/03 08:32, , 1F
05/03 08:32, 1F
推
05/03 09:49, , 2F
05/03 09:49, 2F
推
05/03 11:01, , 3F
05/03 11:01, 3F
推
05/03 11:09, , 4F
05/03 11:09, 4F
推
05/03 11:27, , 5F
05/03 11:27, 5F
推
05/03 15:03, , 6F
05/03 15:03, 6F
VideoCard 近期熱門文章
PTT數位生活區 即時熱門文章